خط مشی دسترسیدرباره ما
ثبت نامثبت نام
راهنماراهنما
فارسی
ورودورود
صفحه اصلیصفحه اصلی
جستجوی مدارک
تمام متن
منابع دیجیتالی
رکورد قبلیرکورد بعدی
library name : انستیتو تغذیه دانشگاه علوم پزشکی شهید بهشتی
Material Type : Latin Articles
Language of Document : English
Record Number : 62249
Doc. No : 911A
Main Entry : JANAT B.
Title & Author : SIMULTANEOUS DETERMINATION OF LEAD, CADMIUM, COPPER AND ZINC IN INFANT FORMULA BY ANODIC STRIPPING VOLTAMMETRY [Article]; BEHFAR A.A.A.,KOMEYLIZADEH H.,SHAFAATI A.R.
Title : IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH (IJPR)
Volume Number : , Vol.8 ؛ No.3
Date : , (2009)
page : : 159 - 162
Abstract : Determination of trace elements in food is of great importance, as some of them have nutritional significance, whilst others are toxic. Long-term exposure to low levels of toxic metals could be important, especially in relation to children.Differential Pulse Anodic Stripping Voltammetry )DPASV( is applied to simultaneous determination of lead, cadmium, copper and zinc in dry ash infant formula in nitric acid at 450▒آ50░آC.Determination of the elements was made in acetate buffer )pH 4.7( with a scan rate of 60 mVs-1 and a pulse height of 50 mV by Hanging Mercury Dropping Electrode )HMDE(. The solution was stirred during pre-electrolysis at -1150 mV )vs. Ag/AgCl( for 90 s and the potential was scanned form -1150 mV to +100 mV)vs. Ag/AgCl(. Precision of the method, expressed by relative standard deviation for lead, cadmium, copper and zinc, was calculated as 4.5percent, 3.5percent, 3.2percent and 5.6percent, respectively. Under these conditions, the limits of detection were 0.005, 0.005, 0.01 and 0.05 mg/kg for lead, cadmium, copper and zinc, respectively. Concentrations of lead, cadmium, copper and zinc in one of the infant formulas available in Iran were 0.384▒آ0.222, 0.359▒آ0.215, 4.436▒آ0.811 and 37.426▒آ8.951 mg/kg )mean▒آSD(, respectively.In our study the concentrations of lead and copper were found significantly higher than those of standard and labelled values )P<0.001(, respectively. Therefore, infant formula manufacturers, by virtue of the role of their products in the infants عnutrition, have been acutely aware for sometime of the need to guard against any heterogeniety and contaminants.
Descriptor : INFANT FORMULA
Descriptor : TRACE ELEMENT
Descriptor : LEAD
Descriptor : CADMIUM
Descriptor : COPPER
Descriptor : ZINC
Descriptor : VOLTAMMETRY
Descriptor : ANODIC STRIPPING
Added Entry : SADEGHI NAFISEH
: OVEYSI M.R
 
 
 
(در صورت عدم وضوح تصویر اینجا را کلیک نمایید)